Yuhong Holding Group Co.,LTD
Offshore and sour gas projects often specify duplex stainless steel as a single line item: "duplex seamless pipe, UNS S31803 / S32205". That shorthand conceals a decision that determines whether a flowline survives twenty years of chloride-rich seawater or fails by stress corrosion cracking (SCC) within three. Duplex 2205 (UNS S32205) and Super Duplex 2507 (UNS S32750) differ by roughly 25 percent in PREN, and by a far larger margin in the lifecycle cost of getting the choice wrong. It governs hydrotest scheduling, welding qualification and warranty exposure.
| Property | Duplex 2205 (S32205) | Super Duplex 2507 (S32750) |
|---|---|---|
| Typical composition | 22% Cr, 3% Mo, 5-6% Ni, 0.15% N | 25% Cr, 3.7% Mo, 7% Ni, 0.27% N |
| PREN (Cr + 3.3Mo + 16N) | approx. 34-36 | approx. 40-43 |
| 0.2% proof strength | min. 450 MPa | min. 550 MPa |
| Critical pitting temperature, ASTM G48 Method A, 6% FeCl3 | approx. 35 C | approx. 60-65 C |
| Wall thickness effect | Baseline | 12-20% thinner for equal pressure rating |
CPT values are typical for ASTM G48 and must be verified against the actual heat. PREN itself is the number most often quoted and least often used correctly: it predicts resistance to chloride pitting and crevice attack in oxygenated seawater, but not SCC resistance in sour service, where temperature, H2S partial pressure and in-situ pH govern under NACE MR0175 / ISO 15156-3, Annex A tables for duplex stainless steels.
Most field failures are not pitting failures but cracking failures driven by residual stress, bad heat treatment or contaminated weld zones. Four controls matter more than grade choice:
Field judgement: over the past five years of reviewing sour service drawings for offshore and Middle East projects, the risks we flag most often are not grade selection errors but residual stress from cold bending never followed by post-forming solution annealing.
Above roughly 60 C, 2205 approaches the ISO 15156-3 chloride SCC limits. Higher H2S partial pressure or lower pH tightens them further; super duplex 2507 or a higher-PREN alloy is required.
Typically 60-65 C by ASTM G48 Method A in 6 percent ferric chloride, against roughly 35 C for 2205. Verify CPT from the actual heat.
No. Post-weld heat treatment embrittles duplex through sigma phase formation. Control residual stress through welding sequence; cold work above 10 percent strain requires post-forming solution annealing.
About the supplier. Founded in 2007, Yuhong Group (Zhejiang Yuhong Weiye Special Steel Co., Ltd.) manufactures stainless steel seamless pipe and tube, duplex and super duplex tube, nickel alloy tube and heat exchanger tube from a production base employing up to 850 people, exporting 80-90 percent of output to oil and gas, power generation and petrochemical customers. SGS, BV or TUV third-party inspection and EN 10204 3.1 certification are available on request.
![]()
Contact Person: Mr. Jikin Cai
Tel: +86-13819835483