logo
Yuhong Holding Group Co.,LTD
About Us
Factory Tour
Quality Control
Contact Us
Company News
Home ProductsCopper Alloy Tube

ASTM B111 C71500 Copper Alloy Seamless Cold Drawn Tube for Shell & Tube Heat Exchangers

ASTM B111 C71500 Copper Alloy Seamless Cold Drawn Tube for Shell & Tube Heat Exchangers

  • ASTM B111 C71500 Copper Alloy Seamless Cold Drawn Tube for Shell & Tube Heat Exchangers
  • ASTM B111 C71500 Copper Alloy Seamless Cold Drawn Tube for Shell & Tube Heat Exchangers
  • ASTM B111 C71500 Copper Alloy Seamless Cold Drawn Tube for Shell & Tube Heat Exchangers
  • ASTM B111 C71500 Copper Alloy Seamless Cold Drawn Tube for Shell & Tube Heat Exchangers
ASTM B111 C71500 Copper Alloy Seamless Cold Drawn Tube for Shell & Tube Heat Exchangers
Product Details:
Place of Origin: CHINA
Brand Name: YUHONG
Certification: ABS, GL, DNV, NK, PED, AD2000, GOST9941-81, CCS, ISO 9001-2008
Model Number: ASTM B111 C71500 COPPER ALLOY TUBE
Payment & Shipping Terms:
Minimum Order Quantity: 500KGS
Price: Negotiable
Packaging Details: Ply-wooden Case /Iron Case
Delivery Time: Depends on quantity
Payment Terms: T/T,L/C
Supply Ability: 800 Tons/ Month
Contact Now
Detailed Product Description
Highlight:

C71500 copper alloy seamless tube

,

ASTM B111 cold drawn tube

,

copper tube for heat exchangers

Product Overview

ASTM B111 C71500 copper alloy seamless tube from Yuhong Group Co., Ltd. is supplied for condenser, evaporator and heat exchanger tube bundles. The purchase description is controlled by UNS C71500, temper, outside diameter, wall thickness, length and test requirements under ASTM B111. The tube is intended for applications where dimensional fit-up and leakage screening are critical.

ASTM B111 controls OD by go/no-go ring gages, with micrometers permitted for point checks and ring gages governing disputes; wall by minimum-wall or nominal-wall ordering rules; length by plus tolerances; and leakage by hydrostatic or pneumatic test. For accurate MOQ, FOB port and Lead Time, confirm UNS C71500, temper, OD x wall x length, test method, certification and quantity at the RFQ stage.

Ordering and Dimensional Controls
Control Item ASTM B111 Requirement
Outside diameter Go/no-go ring gages; micrometer for point check; ring gages final in dispute
Wall thickness Minimum-wall: no point below specified; max plus deviation not over twice Tables 11/12. Nominal-wall: plus/minus per Tables 11/12
Length Not less than specified; plus tolerance per Tables 13/14
Squareness of cut Up to 5/8 in [16 mm] incl: 0.010 in [0.25 mm]; over 5/8 in: 0.016 in/in [mm/mm] of diameter
Workmanship Cut ends deburred unless otherwise ordered; clean and smooth surfaces by temper
Operating and Test Parameters
Parameter ASTM B111 Data
Hydrostatic test P = 2St / (D - 0.8t); need not exceed 1000 psi [7.0 MPa] unless specified
Pneumatic test 60 psig [400 kPa] min for 5 s without leakage; visual detection required
Tension test Full-section specimen preferred; full-size results govern if full-size and machined differ; stressing to yield not over 100 ksi/min [690 MPa/min]
Sampling Lot: 600 tubes or 10,000 lb [4550 kg] or fraction, whichever is greater; portion: two finished lengths
C71500 vs C70600 Procurement Comparison
Item C71500 C70600
ASTM B111 keyword scope Listed Listed
Composition/property data on this page Confirm by RFQ Confirm by RFQ
PO controls UNS, temper, OD, wall, length, tests, certification Same
Commercial terms MOQ, FOB, Lead Time by size and temper Same
Application & Compliance

In condenser and heat exchanger tube bundle assembly, ASTM B111 C71500 tube dimensional tolerances affect fit-up, while hydrostatic or pneumatic testing screens leakage. Specify minimum-wall or nominal-wall ordering because acceptance rules differ; measured values outside specified limits may be cause for rejection.

Certification per 23.1 and a test report per 24.1 are furnished. Chemical analysis uses a composite sample of at least 150 g divided into three equal parts; traceability details should be stated at order placement.

Standards & Certification

Manufactured and inspected to ASTM B111. Certification and test report are provided per ASTM B111 Sections 23.1 and 24.1.

Frequently Asked Questions
How is ASTM B111 C71500 tube hydrotested?

Use P = 2St/(D - 0.8t), where S is allowable stress. The tube need not be tested over 1000 psi [7.0 MPa] unless specified.

Should I order minimum wall or nominal wall?

Minimum-wall orders require no point below specified wall and max plus deviation not over twice Tables 11/12. Nominal-wall orders use plus/minus tolerances in Tables 11/12.

What should an RFQ include for accurate MOQ, FOB and Lead Time?

UNS C71500, temper, OD x wall x length, minimum or nominal wall, test method, certification and quantity.

Packaging & Shipping

Material is separated by size, composition and temper, prepared for common carrier, and marked with purchase order number, alloy designation, temper, size, shape, total length or piece count, and supplier name; specification number when specified.

ASTM B111 C71500 copper alloy seamless cold drawn tubes bundled and prepared for shipment

Contact Details
Yuhong Group Co.,Ltd

Contact Person: Mr. Jikin Cai

Tel: +86-13819835483

Fax: 0086-574-88017980

Send your inquiry directly to us (0 / 3000)